IS-code recommendation for slab as per IS-456:2000

 Codal provision /IS-CODE recommendation for slab as per IS-456:2000

In this article we discussed Codal provision /IS-CODE recommendation for slab as per IS-456:2000

Minimum area of reinforcement 

for  Fe-415 = 0.12% of gross area(B*D) 
for  Fe-250 = 0.15% of gross area(B*D)

Maximum area of reinforcement = 4% (not given in IS-code)

Maximum diameter of steel bars in slab = Thickness of slab/8

Maximum spacing of the reinforcement in main bars are minimum of :-
  1. 3d
  2. 300mm
Maximum spacing of the reinforcement in distribution bars are minimum of :-
  1. 5d
  2. 300
d= effective depth of slab( total depth - effective cover)
IS-code recommendation for slab as per IS-456:2000 IS-code recommendation for slab as per IS-456:2000 Reviewed by Digitech education on April 29, 2022 Rating: 5